Chapter 6: Peripheral Devices & Accessories
Installation—Chargers and Docking Stations
176 Psion Teklogix Omnii XT10 Hand-Held Computer User Manual
Batteries shipped from the factory are charged to approximately 40% of capacity. Lithium-
ion battery packs must be fully charged before use. These batteries can be charged with a
variety of chargers and docking stations. Currently the following are available:
The Snap Module is a mobile adaptor for Omnii. Three models are available—see
“Snap Modules” on page 177.
The AC Wall Adaptor operates as an AC power source and also charges the battery
installed in the unit—see “AC Wall Adaptor - Model No. ST1050” on page 179.
The Vehicle Power Outlet Adaptor powers Omnii and recharges the battery using power
drawn from your vehicle’s automotive power outlet—see “Vehicle Power Outlet
Adaptor - Model ST3113” on page 179.
The Desktop Docking Stations operate as both chargers and docking stations. Operating
as a charger, both the battery installed in Omnii and a spare battery can be charged. Pri-
ority is given to charging the hand-held's battery. See “Desktop Docking Stations -
Models ST4002 and ST4003” on page 180.
Normally it takes 3 to 4 hours to charge a battery. The Omnii intelligent charging system
protects the battery from over-charging by terminating the charge process when the battery
is at maximum capacity.
Table 6.5 Omnii Internal Battery Charging Times
6.5.3 Installation—Chargers and Docking Stations
When installing a charger or docking station, consider the following guidelines.
Keep chargers and docking stations away from excessive dirt, dust and contaminants.
Chargers will not charge batteries outside an ambient temperature range of 0°C to 40°C
(32°F to 104°F). It is recommended that the charger or docking station be operated at
room temperature—between 18°C and 25°C (64°F to 77°F) for maximum performance.
% Charge Completed During Sleep Mode While Operating
100% 4 hrs.
8 hrs.
75% 2.5 hrs. 6 hrs.
Important: To avoid damaging the battery, chargers will not begin the charge process
until the battery temperature is between 0°C to 45°C (32°F to 113°F).